ISO 4723:2023

International Standard   Current Edition
· Approved on 07 November 2023 ·

Water quality — Actinium-227 — Test method using alpha-spectrometry

Radiation measurements
Including dosimetry

ISO 4723:2023 Files

null Pages
Current Edition

ISO 4723:2023 Scope

This document specifies a test method to determine the activity concentration of 227Ac in all types of waters by alpha spectrometry.

The test method is applicable to test samples of supply/drinking water, rainwater, surface and ground water, marine water, as well as cooling water, industrial water, domestic, and industrial wastewater after proper sampling and handling and test sample preparation (see ISO 5667-1, ISO 5667-3, ISO 5667-10). Filtration of the test sample is necessary.

The detection limit depends on the sample volume, the instrument used, the background count rate, the detection efficiency, the counting time, the chemical yield, and the progeny ingrowth. The method described in this document, using currently available alpha spectrometry apparatus, has a detection limit of approximately 0,03 Bq·l−1, when directly measuring the alpha peak of 227Ac. This detection limit is lower than the WHO criteria for safe consumption of drinking water for any actinide alpha emitter (0,1 Bq·l−1).[4] This value can be achieved with a counting time of 48 h for a sample volume of 1 l.

Only a small fraction of 227Ac decays through alpha emissions (~1,42 %). An option to lower the detection limit of the method is to wait, let the progenies of 227Ac grow in, and measure an alpha progeny peak of 227Ac (e.g. 215Po). This is a longer technique, but a lower detection limit of approximately 0,000 2 Bq·l−1 can be obtained by re-counting the sample approximately 90 days after purification. The sample can be re-counted before 90 days, but with a higher detection limit.

The test method(s) described in this document can be used during planned, existing and emergency exposure situations as well as for wastewaters and liquid effluents with specific modifications that can increase the overall uncertainty, detection limit and threshold. For an emergency situation, it is preferable to reduce the counting time rather than the sample volume.

The analysis of 227Ac adsorbed to suspended matter is not covered by this document.

Best Sellers

GSO 150-2:2013
 
Gulf Standard
Expiration dates for food products - Part 2 : Voluntary expiration dates
BH GSO 150-2:2015
GSO 150-2:2013 
Bahraini Standard
Expiration dates for food products - Part 2 : Voluntary expiration dates
BH GSO 150-1:2015
GSO 150-1:2013 
Bahraini Technical Regulation
Expiration dates for food products -Part 1 : Mandatory expiration dates
GSO 150-1:2013
 
Gulf Technical Regulation
Expiration dates for food products -Part 1 : Mandatory expiration dates

Recently Published

ISO/IEC 4879:2024
 
International Standard
Information technology — Quantum computing — Vocabulary
ISO 16502-1:2024
 
International Standard
Furniture — Assessment of the ignitability of mattresses and upholstered bed bases — Part 1: Ignition source: smouldering cigarette
ISO 13680:2024
 
International Standard
Oil and gas industries including lower carbon energy — Corrosion-resistant alloy seamless products for use as casing, tubing, coupling stock and accessory material — Technical delivery conditions
ISO 17097:2024
 
International Standard
3-D human body scan data — Methods for the processing of human body scan data